Mechanical Parking Garage Dimensions–Industry Standard Series I
Want to build a public parking space and feel like the space can be completely customised to your needs?
The answer is going to disappoint you.
According to national standards “Technical code for mechanical parking garage engineering”,the dimensions and mass of the models of mechanical parking garages can be according to the table must be based on the parameters in the table.
JGJ/T 326-2014
- X is a small car;
- Z is a medium-sized car;
- D is a large car;
- T is a very large car;
- C is a super-large car;
- K is a bus
Duplicate parking garage entrances and driveway design should be in accordance with the current industry standards, ‘automotive garage building design specifications’ JGJ 100 of the relevant provisions of the implementation;
For the use of lift and traverse type and simple lift type parking equipment mechanical parking garage, the size of the entrance and exit site in front of the car parking space should meet the requirements of the vehicle steering into the car carrier plate, and its width should not be less than 6000mm
automatic parking garage entrance and exit doorway net width should not be less than the parking equipment suitable parking type width plus 500mm, and should not be less than 2500mm, net height should not be less than 2000mm;
fully automatic parking garage entrance and exit site can not meet the vehicle straight in and out, can be set at the entrance and exit of the rotary disc, and should be based on the rotary disc equipment to determine the size of the pit to install the rotary disc;
mechanical parking garage personnel evacuation exit and vehicle evacuation exit should be set up separately. 3 fully automatic parking garage entrance and exit doorway net width should not be less than the parking equipment suitable for parking type width plus 500mm, and should not be less than 2,500mm, net height should not be less than 2,000mm;
fully automatic parking garage entrance and exit site can not meet the vehicle straight in and out, can be set at the entrance and exit of the rotary disc, and should be based on the rotary disc equipment to determine the size of the pit to install the rotary disc;
Mechanical parking garage personnel evacuation exit and vehicle evacuation exit should be set up separately.